Solar plant: site data

Solar power plant in Verkhnii Naholchyk, Rovenkivskyi Raion, Luhansk Oblast

Verkhnii Naholchyk: 1,157 kWh per kWp a year, tilt 36° facing south (PVGIS). 0.7% above the oblast median (1,150). #30 of 96 in the rayon, #139 of 964 in the oblast.

Rovenky, the rayon centre, is 21 km away. 178 m above sea level. 21 km away: Rovenky, the nearest bigger centre, the same 1,157. Snow and wind from the nearest regional centre in the DBN — Запоріжжя, 295 km. 10.27 m between rows, pitch 14.14 m (latitude 48.1°).

Yield of 1 kWp
1,157kWh/year
Tilt
36°facing south
10 kW
11,573kWh/year
Row pitch
14.14m · GCR 0.34
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,110 / 460Pa

Ground frame designer

A ground frame for a solar plant: Verkhnii Naholchyk

The designer opens with this place’s coordinates, latitude 48.1° for the row spacing and the DBN loads of the nearest regional centre — Запоріжжя, 295 km: snow 1,110 Pa, wind 460 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

39Jan57Feb87Mar115Apr136May141Jun145Jul148Aug124Sep89Oct47Nov29Dec

August: 148 kWh/kWp, December: 29 — 5.1 times less.

December: 29 against 26 in the oblast, 11.5% more.

Verkhnii Naholchyk: plants, kWh
kWpA yearAugustDecember
55,787740145
1011,5731,480290
1517,3602,220435

Snow and wind: Запоріжжя

Example: a 10 kW ground frame

For the loads of Zaporizhzhia: 11.16 kWp, 18 panels, 382 kg of steel, 14 piles, materials ≈ 50,687 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Rovenkivskyi RaionLuhansk Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.