Solar plant: site data
Solar power plant in Novoyelyzavetivka, Rovenkivskyi Raion, Luhansk Oblast
Novoyelyzavetivka: 1,156 kWh per kWp a year, tilt 36° facing south (PVGIS). 0.5% above the oblast median (1,150). #44 of 96 in the rayon, #183 of 964 in the oblast.
Rovenky, the rayon centre, is 41 km away. 209 m above sea level. 41 km away: Rovenky, the nearest bigger centre, the same 1,157. Snow and wind from the nearest regional centre in the DBN — Запоріжжя, 276 km. 10.28 m between rows, pitch 14.15 m (latitude 48.1°).
- Yield of 1 kWp
- 1,156kWh/year
- Tilt
- 36°facing south
- 10 kW
- 11,559kWh/year
- Row pitch
- 14.15m · GCR 0.34
- T_min
- -42 °Cregion II, south-eastern
- Snow S₀ / wind W₀
- 1,110 / 460Pa
Ground frame designer
A ground frame for a solar plant: Novoyelyzavetivka
The designer opens with this place’s coordinates, latitude 48.1° for the row spacing and the DBN loads of the nearest regional centre — Запоріжжя, 276 km: snow 1,110 Pa, wind 460 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
August: 148 kWh/kWp, December: 28 — 5.3 times less.
November: 47 against 43 in the oblast, 9.3% more.
| kWp | A year | August | December |
|---|---|---|---|
| 5 | 5,780 | 740 | 140 |
| 10 | 11,559 | 1,480 | 280 |
| 15 | 17,339 | 2,220 | 420 |
Example: a 10 kW ground frame
For the loads of Zaporizhzhia: 11.16 kWp, 18 panels, 382 kg of steel, 14 piles, materials ≈ 50,687 UAH.
How these numbers are computed
Nearby
- Korinne2 km1,155 kWh/kWp
- Kniahynivka3 km1,155 kWh/kWp
- Khrustalne6 km1,154 kWh/kWp
- Miusynsk6 km1,155 kWh/kWp
- Bokovo-Khrustalne7 km1,155 kWh/kWp
- Andriivka8 km1,160 kWh/kWp
All places: Rovenkivskyi RaionLuhansk Oblast: rayons and towns
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.