Solar plant: site data
Solar power plant in Zabuchchia, Buchanskyi Raion, Kyiv Oblast
Zabuchchia: 1,104 kWh per kWp a year, tilt 38° 3° east of south (PVGIS). 1.6% below the oblast median (1,122). #108 of 143 in the rayon, #911 of 1071 in the oblast.
Bucha, the rayon centre, is 6 km away. 136 m above sea level. 6 km away: Bucha, the nearest bigger centre, 1,092 — 1.1% more here. Snow and wind from the nearest regional centre in the DBN — Київ, 25 km. 12.86 m between rows, pitch 16.63 m (latitude 50.5°).
- Yield of 1 kWp
- 1,104kWh/year
- Tilt
- 38°3° east of south
- 10 kW
- 11,041kWh/year
- Row pitch
- 16.63m · GCR 0.29
- T_min
- -40 °Cregion I, north-western
- Snow S₀ / wind W₀
- 1,550 / 370Pa
Ground frame designer
A ground frame for a solar plant: Zabuchchia
The designer opens with this place’s coordinates, latitude 50.5° for the row spacing and the DBN loads of the nearest regional centre — Київ, 25 km: snow 1,550 Pa, wind 370 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
June: 140 kWh/kWp, December: 27 — 5.2 times less.
January: 36 against 34 in the oblast, 5.9% more.
| kWp | A year | June | December |
|---|---|---|---|
| 5 | 5,521 | 700 | 135 |
| 10 | 11,041 | 1,400 | 270 |
| 15 | 16,562 | 2,100 | 405 |
Example: a 10 kW ground frame
For the loads of Kyiv: 11.16 kWp, 18 panels, 376 kg of steel, 12 piles, materials ≈ 47,122 UAH.
How these numbers are computed
Nearby
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.