Solar plant: site data
Solar power plant in Volodarka, Bilotserkivskyi Raion, Kyiv Oblast
Volodarka: 1,125 kWh per kWp a year, tilt 37° 4° east of south (PVGIS). Exactly the oblast median (1,122). #145 of 260 in the rayon, #451 of 1071 in the oblast.
Bila Tserkva, the rayon centre, is 34 km away. 173 m above sea level. 34 km away: Bila Tserkva, the nearest bigger centre, the same 1,122. Snow and wind from the nearest regional centre in the DBN — Вінниця, 109 km. 11.66 m between rows, pitch 15.48 m (latitude 49.5°).
- Yield of 1 kWp
- 1,125kWh/year
- Tilt
- 37°4° east of south
- 10 kW
- 11,246kWh/year
- Row pitch
- 15.48m · GCR 0.31
- T_min
- -40 °Cregion I, north-western
- Snow S₀ / wind W₀
- 1,360 / 470Pa
Ground frame designer
A ground frame for a solar plant: Volodarka
The designer opens with this place’s coordinates, latitude 49.5° for the row spacing and the DBN loads of the nearest regional centre — Вінниця, 109 km: snow 1,360 Pa, wind 470 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
July: 143 kWh/kWp, December: 30 — 4.8 times less.
December: 30 against 27 in the oblast, 11.1% more.
| kWp | A year | July | December |
|---|---|---|---|
| 5 | 5,623 | 715 | 150 |
| 10 | 11,246 | 1,430 | 300 |
| 15 | 16,869 | 2,145 | 450 |
Example: a 10 kW ground frame
For the loads of Vinnytsia: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.
How these numbers are computed
Nearby
- Rachky3 km1,131 kWh/kWp
- Lohvyn4 km1,125 kWh/kWp
- Zavadivka4 km1,131 kWh/kWp
- Berezna5 km1,122 kWh/kWp
- Tarhan7 km1,125 kWh/kWp
- Mykhailivka8 km1,122 kWh/kWp
All places: Bilotserkivskyi RaionKyiv Oblast: rayons and towns
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.