Solar plant: site data

Solar power plant in Nova Makivka, Bilotserkivskyi Raion, Kyiv Oblast

Nova Makivka: 1,135 kWh per kWp a year, tilt 37° 3° east of south (PVGIS). 1.2% above the oblast median (1,122). #29 of 260 in the rayon, #140 of 1071 in the oblast.

Bila Tserkva, the rayon centre, is 33 km away. 171 m above sea level. 33 km away: Bila Tserkva, the nearest bigger centre, 1,122 — 1.2% more here. Snow and wind from the nearest regional centre in the DBN — Київ, 75 km. 11.88 m between rows, pitch 15.70 m (latitude 49.8°).

Yield of 1 kWp
1,135kWh/year
Tilt
37°3° east of south
10 kW
11,354kWh/year
Row pitch
15.70m · GCR 0.30
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,550 / 370Pa

Ground frame designer

A ground frame for a solar plant: Nova Makivka

The designer opens with this place’s coordinates, latitude 49.8° for the row spacing and the DBN loads of the nearest regional centre — Київ, 75 km: snow 1,550 Pa, wind 370 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

34Jan56Feb95Mar117Apr138May141Jun146Jul141Aug114Sep85Oct37Nov30Dec

July: 146 kWh/kWp, December: 30 — 4.9 times less.

December: 30 against 27 in the oblast, 11.1% more.

Nova Makivka: plants, kWh
kWpA yearJulyDecember
55,677730150
1011,3541,460300
1517,0312,190450

Snow and wind: Київ

Example: a 10 kW ground frame

For the loads of Kyiv: 11.16 kWp, 18 panels, 376 kg of steel, 12 piles, materials ≈ 47,122 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Bilotserkivskyi RaionKyiv Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.