Solar plant: site data

Solar power plant in Lukianivka, Bilotserkivskyi Raion, Kyiv Oblast

Lukianivka: 1,136 kWh per kWp a year, tilt 37° 3° east of south (PVGIS). 1.3% above the oblast median (1,122). #25 of 260 in the rayon, #127 of 1071 in the oblast.

Bila Tserkva, the rayon centre, is 46 km away. 217 m above sea level. 34 km away: Lysyanka, the nearest bigger centre, 1,148 — 1.0% less here. Snow and wind from the nearest regional centre in the DBN — Київ, 105 km. 11.64 m between rows, pitch 15.46 m (latitude 49.5°).

Yield of 1 kWp
1,136kWh/year
Tilt
37°3° east of south
10 kW
11,362kWh/year
Row pitch
15.46m · GCR 0.31
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,550 / 370Pa

Ground frame designer

A ground frame for a solar plant: Lukianivka

The designer opens with this place’s coordinates, latitude 49.5° for the row spacing and the DBN loads of the nearest regional centre — Київ, 105 km: snow 1,550 Pa, wind 370 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

32Jan55Feb95Mar119Apr139May143Jun146Jul142Aug115Sep85Oct37Nov28Dec

July: 146 kWh/kWp, December: 28 — 5.2 times less.

January: 32 against 34 in the oblast, 5.9% less.

Lukianivka: plants, kWh
kWpA yearJulyDecember
55,681730140
1011,3621,460280
1517,0432,190420

Snow and wind: Київ

Example: a 10 kW ground frame

For the loads of Kyiv: 11.16 kWp, 18 panels, 376 kg of steel, 12 piles, materials ≈ 47,122 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Bilotserkivskyi RaionKyiv Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.