Solar plant: site data

Solar power plant in Oreanda, Yaltynskyi Raion, Autonomous Republic of Crimea

Oreanda: 1,308 kWh per kWp a year, tilt 34° 4° east of south (PVGIS). 1.9% above the oblast median (1,284). #35 of 58 in the rayon, #285 of 1025 in the oblast.

Yalta, the rayon centre, is 6 km away. 197 m above sea level. 6 km away: Yalta, the nearest bigger centre, the same 1,313. Snow and wind from the nearest regional centre in the DBN — Херсон, 270 km. 7.79 m between rows, pitch 11.76 m (latitude 44.5°).

Yield of 1 kWp
1,308kWh/year
Tilt
34°4° east of south
10 kW
13,080kWh/year
Row pitch
11.76m · GCR 0.41
T_min
-20 °Cregion IV, Southern coast of Crimea
Snow S₀ / wind W₀
760 / 480Pa

Ground frame designer

A ground frame for a solar plant: Oreanda

The designer opens with this place’s coordinates, latitude 44.5° for the row spacing and the DBN loads of the nearest regional centre — Херсон, 270 km: snow 760 Pa, wind 480 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

49Jan65Feb105Mar132Apr146May152Jun161Jul159Aug132Sep100Oct59Nov47Dec

July: 161 kWh/kWp, December: 47 — 3.4 times less.

November: 59 against 63 in the oblast, 6.3% less.

Oreanda: plants, kWh
kWpA yearJulyDecember
56,540805235
1013,0801,610470
1519,6202,415705

Snow and wind: Херсон

Example: a 10 kW ground frame

For the loads of Kherson: 11.16 kWp, 18 panels, 349 kg of steel, 12 piles, materials ≈ 47,980 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Yaltynskyi RaionAutonomous Republic of Crimea: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.