Solar plant: site data

Solar power plant in Troianka, Holovanivskyi Raion, Kirovohrad Oblast

Troianka: 1,155 kWh per kWp a year, tilt 36° 4° east of south (PVGIS). Exactly the oblast median (1,157). #90 of 171 in the rayon, #434 of 708 in the oblast.

Hayvoron, the rayon centre, is 58 km away. 138 m above sea level. 14 km away: Holovanivsk, the nearest bigger centre, the same 1,160. Snow and wind from the nearest regional centre in the DBN — Кропивницький, 119 km. 10.50 m between rows, pitch 14.37 m (latitude 48.4°).

Yield of 1 kWp
1,155kWh/year
Tilt
36°4° east of south
10 kW
11,554kWh/year
Row pitch
14.37m · GCR 0.33
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,230 / 410Pa

Ground frame designer

A ground frame for a solar plant: Troianka

The designer opens with this place’s coordinates, latitude 48.4° for the row spacing and the DBN loads of the nearest regional centre — Кропивницький, 119 km: snow 1,230 Pa, wind 410 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

35Jan52Feb94Mar120Apr138May142Jun149Jul145Aug119Sep90Oct42Nov30Dec

July: 149 kWh/kWp, December: 30 — 5.0 times less.

December: 30 against 28 in the oblast, 7.1% more.

Troianka: plants, kWh
kWpA yearJulyDecember
55,777745150
1011,5541,490300
1517,3312,235450

Snow and wind: Кропивницький

Example: a 10 kW ground frame

For the loads of Kropyvnytskyi: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 48,082 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Holovanivskyi RaionKirovohrad Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.