Solar plant: site data

Solar power plant in Tavrivka, Oleksandriiskyi Raion, Kirovohrad Oblast

Tavrivka: 1,150 kWh per kWp a year, tilt 35° 2° east of south (PVGIS). 0.6% below the oblast median (1,157). #188 of 191 in the rayon, #595 of 708 in the oblast.

Oleksandriya, the rayon centre, is 21 km away. 122 m above sea level. 21 km away: Oleksandriya, the nearest bigger centre, 1,156 — 0.5% less here. Snow and wind from the nearest regional centre in the DBN — Кропивницький, 85 km. 10.42 m between rows, pitch 14.34 m (latitude 48.6°).

Yield of 1 kWp
1,150kWh/year
Tilt
35°2° east of south
10 kW
11,504kWh/year
Row pitch
14.34m · GCR 0.33
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,230 / 410Pa

Ground frame designer

A ground frame for a solar plant: Tavrivka

The designer opens with this place’s coordinates, latitude 48.6° for the row spacing and the DBN loads of the nearest regional centre — Кропивницький, 85 km: snow 1,230 Pa, wind 410 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

33Jan51Feb89Mar119Apr140May145Jun151Jul148Aug121Sep89Oct40Nov25Dec

July: 151 kWh/kWp, December: 25 — 6.0 times less.

December: 25 against 28 in the oblast, 10.7% less.

Tavrivka: plants, kWh
kWpA yearJulyDecember
55,752755125
1011,5041,510250
1517,2562,265375

Snow and wind: Кропивницький

Example: a 10 kW ground frame

For the loads of Kropyvnytskyi: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 48,082 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Oleksandriiskyi RaionKirovohrad Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.