Solar power plant in Sukhyi Tashlyk, Holovanivskyi Raion, Kirovohrad Oblast

Sukhyi Tashlyk: 1,157 kWh per kWp a year, tilt 36° 4° east of south (PVGIS). Exactly the oblast median (1,157). #75 of 171 in the rayon, #382 of 708 in the oblast.

Hayvoron, the rayon centre, is 62 km away. 151 m above sea level. 14 km away: Vilshanka, the nearest bigger centre, the same 1,158. Snow and wind from the nearest regional centre in the DBN — Кропивницький, 121 km. 10.37 m between rows, pitch 14.24 m (latitude 48.2°).

Yield of 1 kWp
1,157kWh/year
Tilt
36°4° east of south
10 kW
11,568kWh/year
Row pitch
14.24m · GCR 0.34
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,230 / 410Pa

Ground frame designer

A ground frame for a solar plant: Sukhyi Tashlyk

The designer opens with this place’s coordinates, latitude 48.2° for the row spacing and the DBN loads of the nearest regional centre — Кропивницький, 121 km: snow 1,230 Pa, wind 410 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

33Jan52Feb94Mar121Apr139May141Jun149Jul146Aug119Sep91Oct41Nov29Dec

July: 149 kWh/kWp, December: 29 — 5.1 times less.

January: 33 against 35 in the oblast, 5.7% less.

Sukhyi Tashlyk: plants, kWh
kWpA yearJulyDecember
55,784745145
1011,5681,490290
1517,3522,235435

Snow and wind: Кропивницький

Example: a 10 kW ground frame

For the loads of Kropyvnytskyi: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 48,082 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Holovanivskyi RaionKirovohrad Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.