Solar plant: site data

Solar power plant in Holovanivsk, Holovanivskyi Raion, Kirovohrad Oblast

Holovanivsk: 1,160 kWh per kWp a year, tilt 36° 4° east of south (PVGIS). Exactly the oblast median (1,157). #44 of 171 in the rayon, #281 of 708 in the oblast.

Hayvoron, the rayon centre, is 44 km away. 166 m above sea level. 18 km away: Blahovishchenske, the nearest bigger centre, the same 1,163. Snow and wind from the nearest regional centre in the DBN — Кропивницький, 134 km. 10.49 m between rows, pitch 14.36 m (latitude 48.4°).

Yield of 1 kWp
1,160kWh/year
Tilt
36°4° east of south
10 kW
11,596kWh/year
Row pitch
14.36m · GCR 0.33
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,230 / 410Pa

Ground frame designer

A ground frame for a solar plant: Holovanivsk

The designer opens with this place’s coordinates, latitude 48.4° for the row spacing and the DBN loads of the nearest regional centre — Кропивницький, 134 km: snow 1,230 Pa, wind 410 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

37Jan54Feb96Mar120Apr138May142Jun148Jul145Aug118Sep90Oct41Nov30Dec

July: 148 kWh/kWp, December: 30 — 4.9 times less.

December: 30 against 28 in the oblast, 7.1% more.

Holovanivsk: plants, kWh
kWpA yearJulyDecember
55,798740150
1011,5961,480300
1517,3942,220450

Snow and wind: Кропивницький

Example: a 10 kW ground frame

For the loads of Kropyvnytskyi: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 48,082 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Holovanivskyi RaionKirovohrad Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.