Solar plant: site data

Solar power plant in Yaruha, Kamianets-Podilskyi Raion, Khmelnytskyi Oblast

Yaruha: 1,133 kWh per kWp a year, tilt 36° 1° west of south (PVGIS). 3.0% above the oblast median (1,100). #96 of 226 in the rayon, #96 of 1109 in the oblast.

Kamyanets-Podilskyi, the rayon centre, is 15 km away. 210 m above sea level. 15 km away: Kamyanets-Podilskyi, the nearest bigger centre, the same 1,129. Snow and wind from the nearest regional centre in the DBN — Чернівці, 68 km. 10.64 m between rows, pitch 14.51 m (latitude 48.6°).

Yield of 1 kWp
1,133kWh/year
Tilt
36°1° west of south
10 kW
11,326kWh/year
Row pitch
14.51m · GCR 0.33
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,320 / 500Pa

Ground frame designer

A ground frame for a solar plant: Yaruha

The designer opens with this place’s coordinates, latitude 48.6° for the row spacing and the DBN loads of the nearest regional centre — Чернівці, 68 km: snow 1,320 Pa, wind 500 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

37Jan53Feb97Mar119Apr134May136Jun142Jul140Aug115Sep86Oct41Nov32Dec

July: 142 kWh/kWp, December: 32 — 4.4 times less.

January: 37 against 32 in the oblast, 15.6% more.

Yaruha: plants, kWh
kWpA yearJulyDecember
55,663710160
1011,3261,420320
1516,9892,130480

Snow and wind: Чернівці

Example: a 10 kW ground frame

For the loads of Chernivtsi: 11.16 kWp, 18 panels, 412 kg of steel, 16 piles, materials ≈ 54,638 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Kamianets-Podilskyi RaionKhmelnytskyi Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.