Solar plant: site data
Solar power plant in Tymkiv, Kamianets-Podilskyi Raion, Khmelnytskyi Oblast
Tymkiv: 1,121 kWh per kWp a year, tilt 35° 7° west of south (PVGIS). 1.9% above the oblast median (1,100). #172 of 226 in the rayon, #235 of 1109 in the oblast.
Kamyanets-Podilskyi, the rayon centre, is 39 km away. 144 m above sea level. 29 km away: Vinkivtsi, the nearest bigger centre, 1,127 — 0.6% less here. Snow and wind from the nearest regional centre in the DBN — Хмельницький, 70 km. 10.53 m between rows, pitch 14.45 m (latitude 48.8°).
- Yield of 1 kWp
- 1,121kWh/year
- Tilt
- 35°7° west of south
- 10 kW
- 11,210kWh/year
- Row pitch
- 14.45m · GCR 0.33
- T_min
- -40 °Cregion I, north-western
- Snow S₀ / wind W₀
- 1,340 / 500Pa
Ground frame designer
A ground frame for a solar plant: Tymkiv
The designer opens with this place’s coordinates, latitude 48.8° for the row spacing and the DBN loads of the nearest regional centre — Хмельницький, 70 km: snow 1,340 Pa, wind 500 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
July: 143 kWh/kWp, December: 30 — 4.8 times less.
December: 30 against 29 in the oblast, 3.4% more.
| kWp | A year | July | December |
|---|---|---|---|
| 5 | 5,605 | 715 | 150 |
| 10 | 11,210 | 1,430 | 300 |
| 15 | 16,815 | 2,145 | 450 |
Example: a 10 kW ground frame
For the loads of Khmelnytskyi: 11.16 kWp, 18 panels, 415 kg of steel, 16 piles, materials ≈ 55,054 UAH.
How these numbers are computed
Nearby
- Otrokiv2 km1,139 kWh/kWp
- Buchaia4 km1,138 kWh/kWp
- Horodyshche5 km1,134 kWh/kWp
- Lysets5 km1,141 kWh/kWp
- Zagoryany5 km1,142 kWh/kWp
- Sokilets5 km1,110 kWh/kWp
All places: Kamianets-Podilskyi RaionKhmelnytskyi Oblast: rayons and towns
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.