Solar plant: site data

Solar power plant in Stepivka, Khmelnytskyi Raion, Khmelnytskyi Oblast

Stepivka: 1,124 kWh per kWp a year, tilt 36° 1° east of south (PVGIS). 2.2% above the oblast median (1,100). #36 of 576 in the rayon, #196 of 1109 in the oblast.

Khmelnytskyi, the rayon centre, is 67 km away. 288 m above sea level. 23 km away: Letychiv, the nearest bigger centre, 1,113 — 1.0% more here. Snow and wind from the nearest regional centre in the DBN — Вінниця, 44 km. 11.15 m between rows, pitch 15.02 m (latitude 49.2°).

Yield of 1 kWp
1,124kWh/year
Tilt
36°1° east of south
10 kW
11,239kWh/year
Row pitch
15.02m · GCR 0.32
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,360 / 470Pa

Ground frame designer

A ground frame for a solar plant: Stepivka

The designer opens with this place’s coordinates, latitude 49.2° for the row spacing and the DBN loads of the nearest regional centre — Вінниця, 44 km: snow 1,360 Pa, wind 470 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

33Jan52Feb86Mar120Apr138May141Jun143Jul140Aug115Sep86Oct39Nov31Dec

July: 143 kWh/kWp, December: 31 — 4.6 times less.

December: 31 against 29 in the oblast, 6.9% more.

Stepivka: plants, kWh
kWpA yearJulyDecember
55,620715155
1011,2391,430310
1516,8592,145465

Snow and wind: Вінниця

Example: a 10 kW ground frame

For the loads of Vinnytsia: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Khmelnytskyi RaionKhmelnytskyi Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.