Solar plant: site data

Solar power plant in Stara Huta, Khmelnytskyi Raion, Khmelnytskyi Oblast

Stara Huta: 1,126 kWh per kWp a year, tilt 36° 1° east of south (PVGIS). 2.4% above the oblast median (1,100). #17 of 576 in the rayon, #158 of 1109 in the oblast.

Khmelnytskyi, the rayon centre, is 59 km away. 345 m above sea level. 18 km away: Letychiv, the nearest bigger centre, 1,113 — 1.2% more here. Snow and wind from the nearest regional centre in the DBN — Вінниця, 52 km. 11.15 m between rows, pitch 15.02 m (latitude 49.2°).

Yield of 1 kWp
1,126kWh/year
Tilt
36°1° east of south
10 kW
11,261kWh/year
Row pitch
15.02m · GCR 0.32
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,360 / 470Pa

Ground frame designer

A ground frame for a solar plant: Stara Huta

The designer opens with this place’s coordinates, latitude 49.2° for the row spacing and the DBN loads of the nearest regional centre — Вінниця, 52 km: snow 1,360 Pa, wind 470 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

36Jan54Feb88Mar120Apr137May139Jun142Jul139Aug114Sep86Oct39Nov32Dec

July: 142 kWh/kWp, December: 32 — 4.4 times less.

January: 36 against 32 in the oblast, 12.5% more.

Stara Huta: plants, kWh
kWpA yearJulyDecember
55,631710160
1011,2611,420320
1516,8922,130480

Snow and wind: Вінниця

Example: a 10 kW ground frame

For the loads of Vinnytsia: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Khmelnytskyi RaionKhmelnytskyi Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.