Solar plant: site data

Solar power plant in Sharivka, Khmelnytskyi Raion, Khmelnytskyi Oblast

Sharivka: 1,106 kWh per kWp a year, tilt 36° 2° east of south (PVGIS). 0.5% above the oblast median (1,100). #167 of 576 in the rayon, #431 of 1109 in the oblast.

Khmelnytskyi, the rayon centre, is 22 km away. 288 m above sea level. 9 km away: Yarmolyntsi, the nearest bigger centre, 1,100 — 0.5% more here. Snow and wind from the nearest regional centre in the DBN — Хмельницький, 22 km. 11.13 m between rows, pitch 15.00 m (latitude 49.2°).

Yield of 1 kWp
1,106kWh/year
Tilt
36°2° east of south
10 kW
11,060kWh/year
Row pitch
15.00m · GCR 0.32
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,340 / 500Pa

Ground frame designer

A ground frame for a solar plant: Sharivka

The designer opens with this place’s coordinates, latitude 49.2° for the row spacing and the DBN loads of the nearest regional centre — Хмельницький, 22 km: snow 1,340 Pa, wind 500 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

32Jan49Feb87Mar118Apr135May138Jun141Jul139Aug114Sep84Oct38Nov32Dec

July: 141 kWh/kWp, January: 32 — 4.4 times less.

December: 32 against 29 in the oblast, 10.3% more.

Sharivka: plants, kWh
kWpA yearJulyJanuary
55,530705160
1011,0601,410320
1516,5902,115480

Snow and wind: Хмельницький

Example: a 10 kW ground frame

For the loads of Khmelnytskyi: 11.16 kWp, 18 panels, 415 kg of steel, 16 piles, materials ≈ 55,054 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Khmelnytskyi RaionKhmelnytskyi Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.