Solar plant: site data

Solar power plant in Ruda-Hirchychnyans'ka, Kamianets-Podilskyi Raion, Khmelnytskyi Oblast

Ruda-Hirchychnyans'ka: 1,129 kWh per kWp a year, tilt 36° 2° east of south (PVGIS). 2.6% above the oblast median (1,100). #122 of 226 in the rayon, #127 of 1109 in the oblast.

Kamyanets-Podilskyi, the rayon centre, is 40 km away. 307 m above sea level. 22 km away: Vinkivtsi, the nearest bigger centre, the same 1,127. Snow and wind from the nearest regional centre in the DBN — Хмельницький, 58 km. 10.87 m between rows, pitch 14.74 m (latitude 48.9°).

Yield of 1 kWp
1,129kWh/year
Tilt
36°2° east of south
10 kW
11,289kWh/year
Row pitch
14.74m · GCR 0.32
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,340 / 500Pa

Ground frame designer

A ground frame for a solar plant: Ruda-Hirchychnyans'ka

The designer opens with this place’s coordinates, latitude 48.9° for the row spacing and the DBN loads of the nearest regional centre — Хмельницький, 58 km: snow 1,340 Pa, wind 500 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

37Jan53Feb91Mar118Apr135May138Jun142Jul140Aug115Sep87Oct39Nov33Dec

July: 142 kWh/kWp, December: 33 — 4.3 times less.

January: 37 against 32 in the oblast, 15.6% more.

Ruda-Hirchychnyans'ka: plants, kWh
kWpA yearJulyDecember
55,645710165
1011,2891,420330
1516,9342,130495

Snow and wind: Хмельницький

Example: a 10 kW ground frame

For the loads of Khmelnytskyi: 11.16 kWp, 18 panels, 415 kg of steel, 16 piles, materials ≈ 55,054 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Kamianets-Podilskyi RaionKhmelnytskyi Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.