Solar plant: site data
Solar power plant in Malynychi, Khmelnytskyi Raion, Khmelnytskyi Oblast
Malynychi: 1,096 kWh per kWp a year, tilt 36° 1° east of south (PVGIS). Exactly the oblast median (1,100). #312 of 576 in the rayon, #672 of 1109 in the oblast.
Khmelnytskyi, the rayon centre, is 11 km away. 303 m above sea level. 11 km away: Khmelnytskyi, the nearest bigger centre, the same 1,099. Snow and wind from the nearest regional centre in the DBN — Хмельницький, 12 km. 11.26 m between rows, pitch 15.13 m (latitude 49.4°).
- Yield of 1 kWp
- 1,096kWh/year
- Tilt
- 36°1° east of south
- 10 kW
- 10,955kWh/year
- Row pitch
- 15.13m · GCR 0.32
- T_min
- -40 °Cregion I, north-western
- Snow S₀ / wind W₀
- 1,340 / 500Pa
Ground frame designer
A ground frame for a solar plant: Malynychi
The designer opens with this place’s coordinates, latitude 49.4° for the row spacing and the DBN loads of the nearest regional centre — Хмельницький, 12 km: snow 1,340 Pa, wind 500 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
July: 141 kWh/kWp, December: 30 — 4.7 times less.
February: 49 against 51 in the oblast, 3.9% less.
| kWp | A year | July | December |
|---|---|---|---|
| 5 | 5,478 | 705 | 150 |
| 10 | 10,955 | 1,410 | 300 |
| 15 | 16,433 | 2,115 | 450 |
Example: a 10 kW ground frame
For the loads of Khmelnytskyi: 11.16 kWp, 18 panels, 415 kg of steel, 16 piles, materials ≈ 55,054 UAH.
How these numbers are computed
Nearby
- Nyzhchi Vovkivtsi3 km1,099 kWh/kWp
- Vyshchi Vovkivtsi3 km1,100 kWh/kWp
- Volytsia4 km1,096 kWh/kWp
- Mats’kivtsi4 km1,099 kWh/kWp
- Kudryntsi5 km1,095 kWh/kWp
- Ryzhulyntsi5 km1,094 kWh/kWp
All places: Khmelnytskyi RaionKhmelnytskyi Oblast: rayons and towns
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.