Solar power plant in Maliivtsi, Kamianets-Podilskyi Raion, Khmelnytskyi Oblast

Maliivtsi: 1,132 kWh per kWp a year, tilt 37° 1° east of south (PVGIS). 2.9% above the oblast median (1,100). #106 of 226 in the rayon, #108 of 1109 in the oblast.

Kamyanets-Podilskyi, the rayon centre, is 46 km away. 289 m above sea level. 19 km away: Vinkivtsi, the nearest bigger centre, the same 1,127. Snow and wind from the nearest regional centre in the DBN — Хмельницький, 47 km. 11.21 m between rows, pitch 15.03 m (latitude 49.0°).

Yield of 1 kWp
1,132kWh/year
Tilt
37°1° east of south
10 kW
11,315kWh/year
Row pitch
15.03m · GCR 0.32
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,340 / 500Pa

Ground frame designer

A ground frame for a solar plant: Maliivtsi

The designer opens with this place’s coordinates, latitude 49.0° for the row spacing and the DBN loads of the nearest regional centre — Хмельницький, 47 km: snow 1,340 Pa, wind 500 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

38Jan54Feb94Mar118Apr135May137Jun141Jul140Aug115Sep86Oct39Nov33Dec

July: 141 kWh/kWp, December: 33 — 4.3 times less.

January: 38 against 32 in the oblast, 18.8% more.

Maliivtsi: plants, kWh
kWpA yearJulyDecember
55,658705165
1011,3151,410330
1516,9732,115495

Snow and wind: Хмельницький

Example: a 10 kW ground frame

For the loads of Khmelnytskyi: 11.16 kWp, 18 panels, 415 kg of steel, 16 piles, materials ≈ 55,054 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Kamianets-Podilskyi RaionKhmelnytskyi Oblast: rayons and towns

Free calculators

Sources