Solar plant: site data

Solar power plant in Letava, Kamianets-Podilskyi Raion, Khmelnytskyi Oblast

Letava: 1,114 kWh per kWp a year, tilt 36° 1° east of south (PVGIS). 1.3% above the oblast median (1,100). #203 of 226 in the rayon, #310 of 1109 in the oblast.

Kamyanets-Podilskyi, the rayon centre, is 32 km away. 263 m above sea level. 32 km away: Kamyanets-Podilskyi, the nearest bigger centre, 1,129 — 1.2% less here. Snow and wind from the nearest regional centre in the DBN — Чернівці, 74 km. 10.88 m between rows, pitch 14.75 m (latitude 48.9°).

Yield of 1 kWp
1,114kWh/year
Tilt
36°1° east of south
10 kW
11,144kWh/year
Row pitch
14.75m · GCR 0.32
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,320 / 500Pa

Ground frame designer

A ground frame for a solar plant: Letava

The designer opens with this place’s coordinates, latitude 48.9° for the row spacing and the DBN loads of the nearest regional centre — Чернівці, 74 km: snow 1,320 Pa, wind 500 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

34Jan53Feb93Mar118Apr133May136Jun141Jul138Aug113Sep85Oct39Nov31Dec

July: 141 kWh/kWp, December: 31 — 4.5 times less.

December: 31 against 29 in the oblast, 6.9% more.

Letava: plants, kWh
kWpA yearJulyDecember
55,572705155
1011,1441,410310
1516,7162,115465

Snow and wind: Чернівці

Example: a 10 kW ground frame

For the loads of Chernivtsi: 11.16 kWp, 18 panels, 412 kg of steel, 16 piles, materials ≈ 54,638 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Kamianets-Podilskyi RaionKhmelnytskyi Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.