Solar plant: site data

Solar power plant in Kuniv, Shepetivskyi Raion, Khmelnytskyi Oblast

Kuniv: 1,077 kWh per kWp a year, tilt 37° 2° east of south (PVGIS). 2.1% below the oblast median (1,100). #287 of 307 in the rayon, #1079 of 1109 in the oblast.

Shepetivka, the rayon centre, is 50 km away. 209 m above sea level. 27 km away: Bilohirya, the nearest bigger centre, 1,086 — 0.9% less here. Snow and wind from the nearest regional centre in the DBN — Рівне, 43 km. 12.32 m between rows, pitch 16.14 m (latitude 50.2°).

Yield of 1 kWp
1,077kWh/year
Tilt
37°2° east of south
10 kW
10,768kWh/year
Row pitch
16.14m · GCR 0.30
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,320 / 520Pa

Ground frame designer

A ground frame for a solar plant: Kuniv

The designer opens with this place’s coordinates, latitude 50.2° for the row spacing and the DBN loads of the nearest regional centre — Рівне, 43 km: snow 1,320 Pa, wind 520 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

33Jan53Feb91Mar116Apr130May131Jun135Jul133Aug109Sep81Oct36Nov28Dec

July: 135 kWh/kWp, December: 28 — 4.8 times less.

June: 131 against 137 in the oblast, 4.4% less.

Kuniv: plants, kWh
kWpA yearJulyDecember
55,384675140
1010,7681,350280
1516,1522,025420

Snow and wind: Рівне

Example: a 10 kW ground frame

For the loads of Rivne: 11.16 kWp, 18 panels, 415 kg of steel, 16 piles, materials ≈ 55,054 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Shepetivskyi RaionKhmelnytskyi Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.