Solar plant: site data

Solar power plant in Dvorets, Shepetivskyi Raion, Khmelnytskyi Oblast

Dvorets: 1,099 kWh per kWp a year, tilt 37° 1° east of south (PVGIS). Exactly the oblast median (1,100). #99 of 307 in the rayon, #568 of 1109 in the oblast.

Shepetivka, the rayon centre, is 38 km away. 256 m above sea level. 13 km away: Bilohirya, the nearest bigger centre, 1,086 — 1.2% more here. Snow and wind from the nearest regional centre in the DBN — Рівне, 67 km. 12.14 m between rows, pitch 15.96 m (latitude 50.1°).

Yield of 1 kWp
1,099kWh/year
Tilt
37°1° east of south
10 kW
10,994kWh/year
Row pitch
15.96m · GCR 0.30
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,320 / 520Pa

Ground frame designer

A ground frame for a solar plant: Dvorets

The designer opens with this place’s coordinates, latitude 50.1° for the row spacing and the DBN loads of the nearest regional centre — Рівне, 67 km: snow 1,320 Pa, wind 520 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

33Jan51Feb91Mar119Apr134May136Jun139Jul137Aug112Sep83Oct36Nov29Dec

July: 139 kWh/kWp, December: 29 — 4.8 times less.

January: 33 against 32 in the oblast, 3.1% more.

Dvorets: plants, kWh
kWpA yearJulyDecember
55,497695145
1010,9941,390290
1516,4912,085435

Snow and wind: Рівне

Example: a 10 kW ground frame

For the loads of Rivne: 11.16 kWp, 18 panels, 415 kg of steel, 16 piles, materials ≈ 55,054 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Shepetivskyi RaionKhmelnytskyi Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.