Solar plant: site data

Solar power plant in Pchilka, Henicheskyi Raion, Kherson Oblast

Pchilka: 1,295 kWh per kWp a year, tilt 36° 2° west of south (PVGIS). 3.3% above the oblast median (1,253). #11 of 167 in the rayon, #106 of 711 in the oblast.

Henichesk, the rayon centre, is 25 km away. 8 m above sea level. 25 km away: Henichesk, the nearest bigger centre, 1,260 — 2.7% more here. Snow and wind from the nearest regional centre in the DBN — Запоріжжя, 169 km. 9.15 m between rows, pitch 13.02 m (latitude 46.3°).

Yield of 1 kWp
1,295kWh/year
Tilt
36°2° west of south
10 kW
12,949kWh/year
Row pitch
13.02m · GCR 0.37
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,110 / 460Pa

Ground frame designer

A ground frame for a solar plant: Pchilka

The designer opens with this place’s coordinates, latitude 46.3° for the row spacing and the DBN loads of the nearest regional centre — Запоріжжя, 169 km: snow 1,110 Pa, wind 460 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

45Jan62Feb108Mar132Apr153May149Jun159Jul159Aug134Sep98Oct56Nov41Dec

July: 159 kWh/kWp, December: 41 — 3.9 times less.

December: 41 against 37 in the oblast, 10.8% more.

Pchilka: plants, kWh
kWpA yearJulyDecember
56,475795205
1012,9491,590410
1519,4242,385615

Snow and wind: Запоріжжя

Example: a 10 kW ground frame

For the loads of Zaporizhzhia: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Henicheskyi RaionKherson Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.