Solar plant: site data

Solar power plant in Novohryhorivka, Henicheskyi Raion, Kherson Oblast

Novohryhorivka: 1,267 kWh per kWp a year, tilt 36° 1° west of south (PVGIS). 1.1% above the oblast median (1,253). #66 of 167 in the rayon, #240 of 711 in the oblast.

Henichesk, the rayon centre, is 30 km away. 10 m above sea level. 30 km away: Henichesk, the nearest bigger centre, 1,260 — 0.5% more here. Snow and wind from the nearest regional centre in the DBN — Запоріжжя, 160 km. 9.20 m between rows, pitch 13.07 m (latitude 46.4°).

Yield of 1 kWp
1,267kWh/year
Tilt
36°1° west of south
10 kW
12,672kWh/year
Row pitch
13.07m · GCR 0.37
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,110 / 460Pa

Ground frame designer

A ground frame for a solar plant: Novohryhorivka

The designer opens with this place’s coordinates, latitude 46.4° for the row spacing and the DBN loads of the nearest regional centre — Запоріжжя, 160 km: snow 1,110 Pa, wind 460 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

43Jan60Feb106Mar128Apr149May146Jun153Jul156Aug131Sep99Oct57Nov39Dec

August: 156 kWh/kWp, December: 39 — 4.0 times less.

December: 39 against 37 in the oblast, 5.4% more.

Novohryhorivka: plants, kWh
kWpA yearAugustDecember
56,336780195
1012,6721,560390
1519,0082,340585

Snow and wind: Запоріжжя

Example: a 10 kW ground frame

For the loads of Zaporizhzhia: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Henicheskyi RaionKherson Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.