Solar plant: site data

Solar power plant in Fedorivka, Henicheskyi Raion, Kherson Oblast

Fedorivka: 1,243 kWh per kWp a year, tilt 36° 2° east of south (PVGIS). 0.8% below the oblast median (1,253). #123 of 167 in the rayon, #464 of 711 in the oblast.

Henichesk, the rayon centre, is 64 km away. 35 m above sea level. 61 km away: Hornostayivka, the nearest bigger centre, 1,236 — 0.5% more here. Snow and wind from the nearest regional centre in the DBN — Херсон, 127 km. 9.32 m between rows, pitch 13.19 m (latitude 46.6°).

Yield of 1 kWp
1,243kWh/year
Tilt
36°2° east of south
10 kW
12,425kWh/year
Row pitch
13.19m · GCR 0.36
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
760 / 480Pa

Ground frame designer

A ground frame for a solar plant: Fedorivka

The designer opens with this place’s coordinates, latitude 46.6° for the row spacing and the DBN loads of the nearest regional centre — Херсон, 127 km: snow 760 Pa, wind 480 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

44Jan59Feb104Mar124Apr144May141Jun152Jul153Aug129Sep99Oct56Nov37Dec

August: 153 kWh/kWp, December: 37 — 4.1 times less.

March: 104 against 106 in the oblast, 1.9% less.

Fedorivka: plants, kWh
kWpA yearAugustDecember
56,213765185
1012,4251,530370
1518,6382,295555

Snow and wind: Херсон

Example: a 10 kW ground frame

For the loads of Kherson: 11.16 kWp, 18 panels, 349 kg of steel, 12 piles, materials ≈ 47,980 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Henicheskyi RaionKherson Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.