Solar plant: site data

Solar power plant in Chervona Poliana, Kakhovskyi Raion, Kherson Oblast

Chervona Poliana: 1,243 kWh per kWp a year, tilt 36° 2° east of south (PVGIS). 0.8% below the oblast median (1,253). #104 of 170 in the rayon, #460 of 711 in the oblast.

Nova Kakhovka, the rayon centre, is 37 km away. 51 m above sea level. 25 km away: Hornostayivka, the nearest bigger centre, 1,236 — 0.5% more here. Snow and wind from the nearest regional centre in the DBN — Херсон, 94 km. 9.44 m between rows, pitch 13.31 m (latitude 46.8°).

Yield of 1 kWp
1,243kWh/year
Tilt
36°2° east of south
10 kW
12,430kWh/year
Row pitch
13.31m · GCR 0.36
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
760 / 480Pa

Ground frame designer

A ground frame for a solar plant: Chervona Poliana

The designer opens with this place’s coordinates, latitude 46.8° for the row spacing and the DBN loads of the nearest regional centre — Херсон, 94 km: snow 760 Pa, wind 480 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

42Jan58Feb106Mar124Apr142May144Jun155Jul154Aug128Sep99Oct54Nov36Dec

July: 155 kWh/kWp, December: 36 — 4.3 times less.

January: 42 against 44 in the oblast, 4.5% less.

Chervona Poliana: plants, kWh
kWpA yearJulyDecember
56,215775180
1012,4301,550360
1518,6452,325540

Snow and wind: Херсон

Example: a 10 kW ground frame

For the loads of Kherson: 11.16 kWp, 18 panels, 349 kg of steel, 12 piles, materials ≈ 47,980 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Kakhovskyi RaionKherson Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.