Solar plant: site data
Solar power plant in Riznykove, Chuhuivskyi Raion, Kharkiv Oblast
Riznykove: 1,113 kWh per kWp a year, tilt 37° facing south (PVGIS). 2.6% below the oblast median (1,142). #219 of 229 in the rayon, #1756 of 1769 in the oblast.
Chuhuyiv, the rayon centre, is 74 km away. 184 m above sea level. 68 km away: Kupyansk, the nearest bigger centre, 1,150 — 3.2% less here. Snow and wind from the nearest regional centre in the DBN — Харків, 92 km. 12.38 m between rows, pitch 16.20 m (latitude 50.3°).
- Yield of 1 kWp
- 1,113kWh/year
- Tilt
- 37°facing south
- 10 kW
- 11,128kWh/year
- Row pitch
- 16.20m · GCR 0.30
- T_min
- -40 °Cregion I, north-western
- Snow S₀ / wind W₀
- 1,600 / 430Pa
Ground frame designer
A ground frame for a solar plant: Riznykove
The designer opens with this place’s coordinates, latitude 50.3° for the row spacing and the DBN loads of the nearest regional centre — Харків, 92 km: snow 1,600 Pa, wind 430 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
July: 145 kWh/kWp, December: 23 — 6.3 times less.
November: 36 against 40 in the oblast, 10.0% less.
| kWp | A year | July | December |
|---|---|---|---|
| 5 | 5,564 | 725 | 115 |
| 10 | 11,128 | 1,450 | 230 |
| 15 | 16,692 | 2,175 | 345 |
Example: a 10 kW ground frame
For the loads of Kharkiv: 11.16 kWp, 18 panels, 385 kg of steel, 12 piles, materials ≈ 51,876 UAH.
How these numbers are computed
Nearby
- Lukashove1 km1,113 kWh/kWp
- Khyzhniakove3 km1,115 kWh/kWp
- Krasnyi Yar3 km1,114 kWh/kWp
- Loshakove4 km1,115 kWh/kWp
- Cherniakiv4 km1,115 kWh/kWp
- Lobanivka5 km1,119 kWh/kWp
All places: Chuhuivskyi RaionKharkiv Oblast: rayons and towns
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.