Solar plant: site data
Solar power plant in Levkivka, Chuhuivskyi Raion, Kharkiv Oblast
Levkivka: 1,143 kWh per kWp a year, tilt 37° facing south (PVGIS). Exactly the oblast median (1,142). #60 of 229 in the rayon, #842 of 1769 in the oblast.
Chuhuyiv, the rayon centre, is 28 km away. 123 m above sea level. 28 km away: Chuhuyiv, the nearest bigger centre, the same 1,144. Snow and wind from the nearest regional centre in the DBN — Харків, 31 km. 11.83 m between rows, pitch 15.65 m (latitude 49.7°).
- Yield of 1 kWp
- 1,143kWh/year
- Tilt
- 37°facing south
- 10 kW
- 11,428kWh/year
- Row pitch
- 15.65m · GCR 0.31
- T_min
- -42 °Cregion II, south-eastern
- Snow S₀ / wind W₀
- 1,600 / 430Pa
Ground frame designer
A ground frame for a solar plant: Levkivka
The designer opens with this place’s coordinates, latitude 49.7° for the row spacing and the DBN loads of the nearest regional centre — Харків, 31 km: snow 1,600 Pa, wind 430 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
July: 146 kWh/kWp, December: 25 — 5.8 times less.
January: 41 against 39 in the oblast, 5.1% more.
| kWp | A year | July | December |
|---|---|---|---|
| 5 | 5,714 | 730 | 125 |
| 10 | 11,428 | 1,460 | 250 |
| 15 | 17,142 | 2,190 | 375 |
Example: a 10 kW ground frame
For the loads of Kharkiv: 11.16 kWp, 18 panels, 385 kg of steel, 12 piles, materials ≈ 51,876 UAH.
How these numbers are computed
Nearby
- Vyrishalnyi2 km1,145 kWh/kWp
- Chemuzhivka2 km1,143 kWh/kWp
- Butivka3 km1,145 kWh/kWp
- Zmiyiv3 km1,145 kWh/kWp
- Vysochynivka5 km1,146 kWh/kWp
- Zidky5 km1,144 kWh/kWp
All places: Chuhuivskyi RaionKharkiv Oblast: rayons and towns
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.