Solar plant: site data

Solar power plant in Kharchenkov, Chuhuivskyi Raion, Kharkiv Oblast

Kharchenkov: 1,128 kWh per kWp a year, tilt 37° 1° east of south (PVGIS). 1.2% below the oblast median (1,142). #179 of 229 in the rayon, #1536 of 1769 in the oblast.

Chuhuyiv, the rayon centre, is 45 km away. 172 m above sea level. 45 km away: Chuhuyiv, the nearest bigger centre, 1,144 — 1.4% less here. Snow and wind from the nearest regional centre in the DBN — Харків, 61 km. 12.25 m between rows, pitch 16.07 m (latitude 50.2°).

Yield of 1 kWp
1,128kWh/year
Tilt
37°1° east of south
10 kW
11,282kWh/year
Row pitch
16.07m · GCR 0.30
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,600 / 430Pa

Ground frame designer

A ground frame for a solar plant: Kharchenkov

The designer opens with this place’s coordinates, latitude 50.2° for the row spacing and the DBN loads of the nearest regional centre — Харків, 61 km: snow 1,600 Pa, wind 430 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

38Jan57Feb96Mar114Apr137May142Jun146Jul143Aug115Sep80Oct37Nov22Dec

July: 146 kWh/kWp, December: 22 — 6.6 times less.

December: 22 against 24 in the oblast, 8.3% less.

Kharchenkov: plants, kWh
kWpA yearJulyDecember
55,641730110
1011,2821,460220
1516,9232,190330

Snow and wind: Харків

Example: a 10 kW ground frame

For the loads of Kharkiv: 11.16 kWp, 18 panels, 385 kg of steel, 12 piles, materials ≈ 51,876 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Chuhuivskyi RaionKharkiv Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.