Solar plant: site data
Solar power plant in Sloboda-Bolekhivska, Kaluskyi Raion, Ivano-Frankivsk Oblast
Sloboda-Bolekhivska: 1,043 kWh per kWp a year, tilt 39° 7° east of south (PVGIS). 4.9% below the oblast median (1,097). #136 of 162 in the rayon, #632 of 700 in the oblast.
Kalush, the rayon centre, is 46 km away. 521 m above sea level — above 500 m the DBN snow and wind are higher. 32 km away: Stryi, the nearest bigger centre, 1,085 — 3.8% less here. Snow and wind from the nearest regional centre in the DBN — Івано-Франківськ, 71 km. 11.71 m between rows, pitch 15.43 m (latitude 49.0°).
- Yield of 1 kWp
- 1,043kWh/year
- Tilt
- 39°7° east of south
- 10 kW
- 10,430kWh/year
- Row pitch
- 15.43m · GCR 0.31
- T_min
- -38 °Cregion IIIA, Carpathian
- Snow S₀ / wind W₀
- 1,410 / 500Pa
Ground frame designer
A ground frame for a solar plant: Sloboda-Bolekhivska
The designer opens with this place’s coordinates, latitude 49.0° for the row spacing and the DBN loads of the nearest regional centre — Івано-Франківськ, 71 km: snow 1,410 Pa, wind 500 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
July: 120 kWh/kWp, December: 40 — 3.0 times less.
May: 110 against 124 in the oblast, 11.3% less.
| kWp | A year | July | December |
|---|---|---|---|
| 5 | 5,215 | 600 | 200 |
| 10 | 10,430 | 1,200 | 400 |
| 15 | 15,645 | 1,800 | 600 |
Snow and wind: Івано-Франківськ
Example: a 10 kW ground frame
For the loads of Ivano-Frankivsk: 11.16 kWp, 18 panels, 410 kg of steel, 16 piles, materials ≈ 54,212 UAH.
How these numbers are computed
Nearby
- Luzhky3 km1,027 kWh/kWp
- Roztochky4 km1,056 kWh/kWp
- Lupa4 km1,019 kWh/kWp
- Tserkovna4 km1,058 kWh/kWp
- Stankivtsi5 km1,055 kWh/kWp
- Bukovets5 km992 kWh/kWp
All places: Kaluskyi RaionIvano-Frankivsk Oblast: rayons and towns
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.