Solar plant: site data

Solar power plant in Zelenyi Luh, Kamianskyi Raion, Dnipropetrovsk Oblast

Zelenyi Luh: 1,166 kWh per kWp a year, tilt 36° 3° east of south (PVGIS). 1.0% below the oblast median (1,177). #243 of 280 in the rayon, #1271 of 1501 in the oblast.

Kamyanske, the rayon centre, is 64 km away. 111 m above sea level. 37 km away: Petrove, the nearest bigger centre, the same 1,169. Snow and wind from the nearest regional centre in the DBN — Дніпро, 96 km. 10.53 m between rows, pitch 14.40 m (latitude 48.4°).

Yield of 1 kWp
1,166kWh/year
Tilt
36°3° east of south
10 kW
11,659kWh/year
Row pitch
14.40m · GCR 0.33
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,340 / 470Pa

Ground frame designer

A ground frame for a solar plant: Zelenyi Luh

The designer opens with this place’s coordinates, latitude 48.4° for the row spacing and the DBN loads of the nearest regional centre — Дніпро, 96 km: snow 1,340 Pa, wind 470 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

35Jan52Feb91Mar118Apr139May145Jun151Jul150Aug123Sep90Oct44Nov28Dec

July: 151 kWh/kWp, December: 28 — 5.4 times less.

November: 44 against 47 in the oblast, 6.4% less.

Zelenyi Luh: plants, kWh
kWpA yearJulyDecember
55,830755140
1011,6591,510280
1517,4892,265420

Snow and wind: Дніпро

Example: a 10 kW ground frame

For the loads of Dnipro: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Kamianskyi RaionDnipropetrovsk Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.