Solar plant: site data

Solar power plant in Vyshneve, Kamianskyi Raion, Dnipropetrovsk Oblast

Vyshneve: 1,166 kWh per kWp a year, tilt 36° 2° east of south (PVGIS). 1.0% below the oblast median (1,177). #248 of 280 in the rayon, #1278 of 1501 in the oblast.

Kamyanske, the rayon centre, is 52 km away. 129 m above sea level. 49 km away: Petrove, the nearest bigger centre, the same 1,169. Snow and wind from the nearest regional centre in the DBN — Дніпро, 84 km. 10.52 m between rows, pitch 14.39 m (latitude 48.4°).

Yield of 1 kWp
1,166kWh/year
Tilt
36°2° east of south
10 kW
11,657kWh/year
Row pitch
14.39m · GCR 0.33
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,340 / 470Pa

Ground frame designer

A ground frame for a solar plant: Vyshneve

The designer opens with this place’s coordinates, latitude 48.4° for the row spacing and the DBN loads of the nearest regional centre — Дніпро, 84 km: snow 1,340 Pa, wind 470 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

34Jan51Feb91Mar118Apr140May145Jun151Jul151Aug123Sep90Oct44Nov27Dec

July: 151 kWh/kWp, December: 27 — 5.6 times less.

November: 44 against 47 in the oblast, 6.4% less.

Vyshneve: plants, kWh
kWpA yearJulyDecember
55,829755135
1011,6571,510270
1517,4862,265405

Snow and wind: Дніпро

Example: a 10 kW ground frame

For the loads of Dnipro: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Kamianskyi RaionDnipropetrovsk Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.