Solar plant: site data

Solar power plant in Vasylivka, Pavlohradskyi Raion, Dnipropetrovsk Oblast

Vasylivka: 1,154 kWh per kWp a year, tilt 36° 2° east of south (PVGIS). 2.0% below the oblast median (1,177). #85 of 89 in the rayon, #1482 of 1501 in the oblast.

Pavlohrad, the rayon centre, is 35 km away. 116 m above sea level. 17 km away: Lozova, the nearest bigger centre, the same 1,153. Snow and wind from the nearest regional centre in the DBN — Дніпро, 87 km. 10.80 m between rows, pitch 14.67 m (latitude 48.8°).

Yield of 1 kWp
1,154kWh/year
Tilt
36°2° east of south
10 kW
11,540kWh/year
Row pitch
14.67m · GCR 0.33
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,340 / 470Pa

Ground frame designer

A ground frame for a solar plant: Vasylivka

The designer opens with this place’s coordinates, latitude 48.8° for the row spacing and the DBN loads of the nearest regional centre — Дніпро, 87 km: snow 1,340 Pa, wind 470 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

34Jan51Feb93Mar115Apr138May143Jun150Jul149Aug121Sep89Oct43Nov27Dec

July: 150 kWh/kWp, December: 27 — 5.6 times less.

November: 43 against 47 in the oblast, 8.5% less.

Vasylivka: plants, kWh
kWpA yearJulyDecember
55,770750135
1011,5401,500270
1517,3102,250405

Snow and wind: Дніпро

Example: a 10 kW ground frame

For the loads of Dnipro: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Pavlohradskyi RaionDnipropetrovsk Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.