Solar plant: site data

Solar power plant in Oleksiivka, Nikopolskyi Raion, Dnipropetrovsk Oblast

Oleksiivka: 1,232 kWh per kWp a year, tilt 36° facing south (PVGIS). 4.6% above the oblast median (1,177). #13 of 135 in the rayon, #14 of 1501 in the oblast.

Nikopol, the rayon centre, is 12 km away. 27 m above sea level. 12 km away: Nikopol, the nearest bigger centre, 1,224 — 0.6% more here. Snow and wind from the nearest regional centre in the DBN — Запоріжжя, 73 km. 9.93 m between rows, pitch 13.80 m (latitude 47.6°).

Yield of 1 kWp
1,232kWh/year
Tilt
36°facing south
10 kW
12,317kWh/year
Row pitch
13.80m · GCR 0.35
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,110 / 460Pa

Ground frame designer

A ground frame for a solar plant: Oleksiivka

The designer opens with this place’s coordinates, latitude 47.6° for the row spacing and the DBN loads of the nearest regional centre — Запоріжжя, 73 km: snow 1,110 Pa, wind 460 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

43Jan59Feb99Mar124Apr146May146Jun154Jul154Aug128Sep93Oct50Nov34Dec

July: 154 kWh/kWp, December: 34 — 4.5 times less.

January: 43 against 35 in the oblast, 22.9% more.

Oleksiivka: plants, kWh
kWpA yearJulyDecember
56,159770170
1012,3171,540340
1518,4762,310510

Snow and wind: Запоріжжя

Example: a 10 kW ground frame

For the loads of Zaporizhzhia: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Nikopolskyi RaionDnipropetrovsk Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.