Solar plant: site data

Solar power plant in Oleksandrivka, Nikopolskyi Raion, Dnipropetrovsk Oblast

Oleksandrivka: 1,220 kWh per kWp a year, tilt 36° 2° east of south (PVGIS). 3.6% above the oblast median (1,177). #43 of 135 in the rayon, #47 of 1501 in the oblast.

Nikopol, the rayon centre, is 25 km away. 24 m above sea level. 25 km away: Nikopol, the nearest bigger centre, the same 1,224. Snow and wind from the nearest regional centre in the DBN — Запоріжжя, 72 km. 10.04 m between rows, pitch 13.91 m (latitude 47.7°).

Yield of 1 kWp
1,220kWh/year
Tilt
36°2° east of south
10 kW
12,195kWh/year
Row pitch
13.91m · GCR 0.34
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,110 / 460Pa

Ground frame designer

A ground frame for a solar plant: Oleksandrivka

The designer opens with this place’s coordinates, latitude 47.7° for the row spacing and the DBN loads of the nearest regional centre — Запоріжжя, 72 km: snow 1,110 Pa, wind 460 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

40Jan57Feb100Mar123Apr143May146Jun152Jul152Aug127Sep94Oct51Nov32Dec

July: 152 kWh/kWp, December: 32 — 4.8 times less.

January: 40 against 35 in the oblast, 14.3% more.

Oleksandrivka: plants, kWh
kWpA yearJulyDecember
56,098760160
1012,1951,520320
1518,2932,280480

Snow and wind: Запоріжжя

Example: a 10 kW ground frame

For the loads of Zaporizhzhia: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed