Solar plant: site data

Solar power plant in Obukhivka, Dniprovskyi Raion, Dnipropetrovsk Oblast

Obukhivka: 1,186 kWh per kWp a year, tilt 37° 2° east of south (PVGIS). 0.7% above the oblast median (1,177). #53 of 240 in the rayon, #345 of 1501 in the oblast.

Dnipro, the rayon centre, is 17 km away. 54 m above sea level. 17 km away: Dnipro, the nearest bigger centre, the same 1,190. Snow and wind from the nearest regional centre in the DBN — Дніпро, 17 km. 10.86 m between rows, pitch 14.68 m (latitude 48.5°).

Yield of 1 kWp
1,186kWh/year
Tilt
37°2° east of south
10 kW
11,855kWh/year
Row pitch
14.68m · GCR 0.33
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,340 / 470Pa

Ground frame designer

A ground frame for a solar plant: Obukhivka

The designer opens with this place’s coordinates, latitude 48.5° for the row spacing and the DBN loads of the nearest regional centre — Дніпро, 17 km: snow 1,340 Pa, wind 470 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

41Jan60Feb97Mar118Apr139May143Jun148Jul149Aug122Sep90Oct47Nov31Dec

August: 149 kWh/kWp, December: 31 — 4.8 times less.

January: 41 against 35 in the oblast, 17.1% more.

Obukhivka: plants, kWh
kWpA yearAugustDecember
55,928745155
1011,8551,490310
1517,7832,235465

Snow and wind: Дніпро

Example: a 10 kW ground frame

For the loads of Dnipro: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Dniprovskyi RaionDnipropetrovsk Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.