Solar plant: site data

Solar power plant in Dovhivka, Nikopolskyi Raion, Dnipropetrovsk Oblast

Dovhivka: 1,186 kWh per kWp a year, tilt 36° 2° east of south (PVGIS). 0.7% above the oblast median (1,177). #125 of 135 in the rayon, #331 of 1501 in the oblast.

Nikopol, the rayon centre, is 40 km away. 67 m above sea level. 40 km away: Nikopol, the nearest bigger centre, 1,224 — 3.1% less here. Snow and wind from the nearest regional centre in the DBN — Запоріжжя, 64 km. 10.16 m between rows, pitch 14.03 m (latitude 47.9°).

Yield of 1 kWp
1,186kWh/year
Tilt
36°2° east of south
10 kW
11,858kWh/year
Row pitch
14.03m · GCR 0.34
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,110 / 460Pa

Ground frame designer

A ground frame for a solar plant: Dovhivka

The designer opens with this place’s coordinates, latitude 47.9° for the row spacing and the DBN loads of the nearest regional centre — Запоріжжя, 64 km: snow 1,110 Pa, wind 460 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

35Jan51Feb96Mar120Apr141May145Jun152Jul152Aug125Sep92Oct49Nov29Dec

July: 152 kWh/kWp, December: 29 — 5.2 times less.

February: 51 against 54 in the oblast, 5.6% less.

Dovhivka: plants, kWh
kWpA yearJulyDecember
55,929760145
1011,8581,520290
1517,7872,280435

Snow and wind: Запоріжжя

Example: a 10 kW ground frame

For the loads of Zaporizhzhia: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Nikopolskyi RaionDnipropetrovsk Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.