Solar plant: site data

Solar power plant in Chervonyi Yar, Kamianskyi Raion, Dnipropetrovsk Oblast

Chervonyi Yar: 1,186 kWh per kWp a year, tilt 36° 2° east of south (PVGIS). 0.8% above the oblast median (1,177). #6 of 280 in the rayon, #322 of 1501 in the oblast.

Kamyanske, the rayon centre, is 20 km away. 99 m above sea level. 20 km away: Kamyanske, the nearest bigger centre, the same 1,184. Snow and wind from the nearest regional centre in the DBN — Дніпро, 47 km. 10.48 m between rows, pitch 14.35 m (latitude 48.4°).

Yield of 1 kWp
1,186kWh/year
Tilt
36°2° east of south
10 kW
11,861kWh/year
Row pitch
14.35m · GCR 0.33
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,340 / 470Pa

Ground frame designer

A ground frame for a solar plant: Chervonyi Yar

The designer opens with this place’s coordinates, latitude 48.4° for the row spacing and the DBN loads of the nearest regional centre — Дніпро, 47 km: snow 1,340 Pa, wind 470 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

35Jan57Feb97Mar119Apr140May145Jun151Jul151Aug124Sep91Oct47Nov30Dec

July: 151 kWh/kWp, December: 30 — 5.0 times less.

December: 30 against 28 in the oblast, 7.1% more.

Chervonyi Yar: plants, kWh
kWpA yearJulyDecember
55,931755150
1011,8611,510300
1517,7922,265450

Snow and wind: Дніпро

Example: a 10 kW ground frame

For the loads of Dnipro: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Kamianskyi RaionDnipropetrovsk Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.