Solar plant: site data

Solar power plant in Chernihivka, Dniprovskyi Raion, Dnipropetrovsk Oblast

Chernihivka: 1,175 kWh per kWp a year, tilt 36° 3° east of south (PVGIS). Exactly the oblast median (1,177). #187 of 240 in the rayon, #904 of 1501 in the oblast.

Dnipro, the rayon centre, is 74 km away. 101 m above sea level. 49 km away: Solone, the nearest bigger centre, 1,184 — 0.7% less here. Snow and wind from the nearest regional centre in the DBN — Запоріжжя, 70 km. 10.25 m between rows, pitch 14.12 m (latitude 48.1°).

Yield of 1 kWp
1,175kWh/year
Tilt
36°3° east of south
10 kW
11,747kWh/year
Row pitch
14.12m · GCR 0.34
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,110 / 460Pa

Ground frame designer

A ground frame for a solar plant: Chernihivka

The designer opens with this place’s coordinates, latitude 48.1° for the row spacing and the DBN loads of the nearest regional centre — Запоріжжя, 70 km: snow 1,110 Pa, wind 460 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

35Jan51Feb93Mar118Apr139May144Jun152Jul152Aug124Sep91Oct48Nov28Dec

July: 152 kWh/kWp, December: 28 — 5.4 times less.

February: 51 against 54 in the oblast, 5.6% less.

Chernihivka: plants, kWh
kWpA yearJulyDecember
55,874760140
1011,7471,520280
1517,6212,280420

Snow and wind: Запоріжжя

Example: a 10 kW ground frame

For the loads of Zaporizhzhia: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Dniprovskyi RaionDnipropetrovsk Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.