Germany: solar plant site data

Solar power plant in Oldenburg, Germany: yield, tilt angle and row spacing

Oldenburg: 988 kWh per kWp a year at the optimal tilt of 40°, 4° east of south (PVGIS). 5.5% below the median of the main cities of Germany (1,045). #184 of 193 main cities of Germany by yield. For comparison, Kyiv: 1,114 kWh/kWp — 11.4% less here.

Oldenburg is in Lower Saxony. Population 159,218 (GeoNames). 10 m above sea level. 40 km away: Bremen, the nearest bigger city, 999 kWh/kWp — 1.1% less here. 16.99 m between rows, pitch 20.65 m, GCR 0.23 (latitude 53.1°).

Yield of 1 kWp
988kWh/year
Tilt
40°4° east of south
10 kW
9,875kWh/year
Row pitch
20.65m · GCR 0.23
Rank in the country
184of 193 cities

Ground frame designer

A ground frame for a solar plant: Oldenburg

Latitude 53.1°: the tilt and the row pitch follow it. Enter the snow and wind for Germany in the designer, by the national annex to the Eurocode.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

29Jan49Feb87Mar118Apr125May122Jun121Jul114Aug95Sep68Oct36Nov25Dec

May: 125 kWh/kWp, December: 25 — 5.0 times less.

January: 29 against the median of 35 for the main cities of Germany, 17.1% less.

Oldenburg: plants, kWh
kWpA yearMayDecember
54,938625125
109,8751,250250
1514,8131,875375

Snow and wind loads

Snow and wind loads for a site in Germany follow DIN EN 1991-1-3/NA (snow load zone, Schneelastzone) and DIN EN 1991-1-4/NA (wind zone, Windzone). Solispec computes loads by the Ukrainian DBN V.1.2-2 only, so this page shows no snow or wind values for Germany: enter the characteristic values from these documents in the designer’s «Own snow S0» and «Own wind W0» fields.

The frame calculation for such a site is preliminary: before installation it must be checked by an engineer who works to the country’s standards.

Nearby cities

Germany: all cities and regions

Sources

Preliminary calculation: a design needs an engineer’s check.