Germany: solar plant site data

Solar power plant in Garbsen, Germany: yield, tilt angle and row spacing

Garbsen: 1,020 kWh per kWp a year at the optimal tilt of 40°, 3° east of south (PVGIS). 2.4% below the median of the main cities of Germany (1,045). #135 of 193 main cities of Germany by yield. For comparison, Kyiv: 1,114 kWh/kWp — 8.4% less here.

Garbsen is in Lower Saxony. Population 63,355 (GeoNames). 49 m above sea level. 10 km away: Hanover, the nearest bigger city, 1,013 kWh/kWp — 0.7% more here. 15.85 m between rows, pitch 19.51 m, GCR 0.25 (latitude 52.4°).

Yield of 1 kWp
1,020kWh/year
Tilt
40°3° east of south
10 kW
10,200kWh/year
Row pitch
19.51m · GCR 0.25
Rank in the country
135of 193 cities

Ground frame designer

A ground frame for a solar plant: Garbsen

Latitude 52.4°: the tilt and the row pitch follow it. Enter the snow and wind for Germany in the designer, by the national annex to the Eurocode.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

32Jan52Feb89Mar119Apr127May125Jun123Jul116Aug98Sep70Oct39Nov29Dec

May: 127 kWh/kWp, December: 29 — 4.4 times less.

November: 39 against the median of 43 for the main cities of Germany, 9.3% less.

Garbsen: plants, kWh
kWpA yearMayDecember
55,100635145
1010,2001,270290
1515,3001,905435

Snow and wind loads

Snow and wind loads for a site in Germany follow DIN EN 1991-1-3/NA (snow load zone, Schneelastzone) and DIN EN 1991-1-4/NA (wind zone, Windzone). Solispec computes loads by the Ukrainian DBN V.1.2-2 only, so this page shows no snow or wind values for Germany: enter the characteristic values from these documents in the designer’s «Own snow S0» and «Own wind W0» fields.

The frame calculation for such a site is preliminary: before installation it must be checked by an engineer who works to the country’s standards.

Nearby cities

Germany: all cities and regions

Sources

Preliminary calculation: a design needs an engineer’s check.