Solar plant: site data

Solar power plant in Shyshkivtsi, Chernivetskyi Raion, Chernivtsi Oblast

Shyshkivtsi: 1,126 kWh per kWp a year, tilt 37° facing south (PVGIS). 1.5% below the oblast median (1,143). #190 of 215 in the rayon, #321 of 422 in the oblast.

Chernivtsi, the rayon centre, is 36 km away. 233 m above sea level. 16 km away: Kitsman, the nearest bigger centre, 1,137 — 1.0% less here. Snow and wind from the nearest regional centre in the DBN — Чернівці, 37 km. 10.86 m between rows, pitch 14.68 m (latitude 48.6°).

Yield of 1 kWp
1,126kWh/year
Tilt
37°facing south
10 kW
11,255kWh/year
Row pitch
14.68m · GCR 0.33
T_min
-38 °Cregion IIIA, Carpathian
Snow S₀ / wind W₀
1,320 / 500Pa

Ground frame designer

A ground frame for a solar plant: Shyshkivtsi

The designer opens with this place’s coordinates, latitude 48.6° for the row spacing and the DBN loads of the nearest regional centre — Чернівці, 37 km: snow 1,320 Pa, wind 500 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

42Jan55Feb93Mar118Apr130May129Jun139Jul135Aug113Sep88Oct46Nov36Dec

July: 139 kWh/kWp, December: 36 — 3.9 times less.

February: 55 against 60 in the oblast, 8.3% less.

Shyshkivtsi: plants, kWh
kWpA yearJulyDecember
55,628695180
1011,2551,390360
1516,8832,085540

Snow and wind: Чернівці

Example: a 10 kW ground frame

For the loads of Chernivtsi: 11.16 kWp, 18 panels, 412 kg of steel, 16 piles, materials ≈ 54,638 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Chernivetskyi RaionChernivtsi Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.