Solar plant: site data
Solar power plant in Lashkivka, Chernivetskyi Raion, Chernivtsi Oblast
Lashkivka: 1,135 kWh per kWp a year, tilt 37° 1° east of south (PVGIS). 0.6% below the oblast median (1,143). #162 of 215 in the rayon, #278 of 422 in the oblast.
Chernivtsi, the rayon centre, is 18 km away. 244 m above sea level. 3 km away: Kitsman, the nearest bigger centre, the same 1,137. Snow and wind from the nearest regional centre in the DBN — Чернівці, 18 km. 10.76 m between rows, pitch 14.58 m (latitude 48.4°).
- Yield of 1 kWp
- 1,135kWh/year
- Tilt
- 37°1° east of south
- 10 kW
- 11,352kWh/year
- Row pitch
- 14.58m · GCR 0.33
- T_min
- -38 °Cregion IIIA, Carpathian
- Snow S₀ / wind W₀
- 1,320 / 500Pa
Ground frame designer
A ground frame for a solar plant: Lashkivka
The designer opens with this place’s coordinates, latitude 48.4° for the row spacing and the DBN loads of the nearest regional centre — Чернівці, 18 km: snow 1,320 Pa, wind 500 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
July: 139 kWh/kWp, December: 36 — 3.9 times less.
February: 57 against 60 in the oblast, 5.0% less.
| kWp | A year | July | December |
|---|---|---|---|
| 5 | 5,676 | 695 | 180 |
| 10 | 11,352 | 1,390 | 360 |
| 15 | 17,028 | 2,085 | 540 |
Example: a 10 kW ground frame
For the loads of Chernivtsi: 11.16 kWp, 18 panels, 412 kg of steel, 16 piles, materials ≈ 54,638 UAH.
How these numbers are computed
Nearby
- Vytylivka2 km1,137 kWh/kWp
- Kitsman3 km1,137 kWh/kWp
- Valyava5 km1,142 kWh/kWp
- Shypyntsi5 km1,143 kWh/kWp
- Sukhoverkhiv5 km1,133 kWh/kWp
- Oshykhliby6 km1,137 kWh/kWp
All places: Chernivetskyi RaionChernivtsi Oblast: rayons and towns
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.