Solar plant: site data

Solar power plant in Yasenivka, Chernihivskyi Raion, Chernihiv Oblast

Yasenivka: 1,102 kWh per kWp a year, tilt 39° 2° east of south (PVGIS). 0.5% below the oblast median (1,108). #287 of 479 in the rayon, #973 of 1558 in the oblast.

Chernihiv, the rayon centre, is 53 km away. 147 m above sea level. 43 km away: Koryukivka, the nearest bigger centre, 1,085 — 1.6% more here. Snow and wind from the nearest regional centre in the DBN — Чернігів, 54 km. 14.82 m between rows, pitch 18.54 m (latitude 51.9°).

Yield of 1 kWp
1,102kWh/year
Tilt
39°2° east of south
10 kW
11,021kWh/year
Row pitch
18.54m · GCR 0.26
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,720 / 410Pa

Ground frame designer

A ground frame for a solar plant: Yasenivka

The designer opens with this place’s coordinates, latitude 51.9° for the row spacing and the DBN loads of the nearest regional centre — Чернігів, 54 km: snow 1,720 Pa, wind 410 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

35Jan61Feb100Mar117Apr139May142Jun139Jul135Aug108Sep73Oct29Nov24Dec

June: 142 kWh/kWp, December: 24 — 5.9 times less.

November: 29 against 33 in the oblast, 12.1% less.

Yasenivka: plants, kWh
kWpA yearJuneDecember
55,511710120
1011,0211,420240
1516,5322,130360

Snow and wind: Чернігів

Example: a 10 kW ground frame

For the loads of Chernihiv: 11.16 kWp, 18 panels, 389 kg of steel, 12 piles, materials ≈ 52,358 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Chernihivskyi RaionChernihiv Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.