Solar plant: site data
Solar power plant in Voronky, Nizhynskyi Raion, Chernihiv Oblast
Voronky: 1,116 kWh per kWp a year, tilt 37° 2° east of south (PVGIS). 0.7% above the oblast median (1,108). #114 of 327 in the rayon, #443 of 1558 in the oblast.
Nizhyn, the rayon centre, is 46 km away. 131 m above sea level. 46 km away: Nizhyn, the nearest bigger centre, 1,108 — 0.7% more here. Snow and wind from the nearest regional centre in the DBN — Київ, 79 km. 12.76 m between rows, pitch 16.58 m (latitude 50.7°).
- Yield of 1 kWp
- 1,116kWh/year
- Tilt
- 37°2° east of south
- 10 kW
- 11,158kWh/year
- Row pitch
- 16.58m · GCR 0.29
- T_min
- -40 °Cregion I, north-western
- Snow S₀ / wind W₀
- 1,550 / 370Pa
Ground frame designer
A ground frame for a solar plant: Voronky
The designer opens with this place’s coordinates, latitude 50.7° for the row spacing and the DBN loads of the nearest regional centre — Київ, 79 km: snow 1,550 Pa, wind 370 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
July: 146 kWh/kWp, December: 24 — 6.1 times less.
March: 90 against 96 in the oblast, 6.3% less.
| kWp | A year | July | December |
|---|---|---|---|
| 5 | 5,579 | 730 | 120 |
| 10 | 11,158 | 1,460 | 240 |
| 15 | 16,737 | 2,190 | 360 |
Example: a 10 kW ground frame
For the loads of Kyiv: 11.16 kWp, 18 panels, 376 kg of steel, 12 piles, materials ≈ 47,122 UAH.
How these numbers are computed
Nearby
- Vepryk3 km1,119 kWh/kWp
- Pluh5 km1,120 kWh/kWp
- Bilotserkivtsi6 km1,119 kWh/kWp
- Katerynivka6 km1,117 kWh/kWp
- Hart6 km1,119 kWh/kWp
- Svydovets6 km1,119 kWh/kWp
All places: Nizhynskyi RaionChernihiv Oblast: rayons and towns
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.