Solar power plant in Selyshche, Koriukivskyi Raion, Chernihiv Oblast

Selyshche: 1,089 kWh per kWp a year, tilt 39° 2° east of south (PVGIS). 1.7% below the oblast median (1,108). #110 of 220 in the rayon, #1217 of 1558 in the oblast.

Koryukivka, the rayon centre, is 23 km away. 119 m above sea level. 23 km away: Koryukivka, the nearest bigger centre, the same 1,085. Snow and wind from the nearest regional centre in the DBN — Чернігів, 61 km. 14.75 m between rows, pitch 18.47 m (latitude 51.9°).

Yield of 1 kWp
1,089kWh/year
Tilt
39°2° east of south
10 kW
10,890kWh/year
Row pitch
18.47m · GCR 0.26
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,720 / 410Pa

Ground frame designer

A ground frame for a solar plant: Selyshche

The designer opens with this place’s coordinates, latitude 51.9° for the row spacing and the DBN loads of the nearest regional centre — Чернігів, 61 km: snow 1,720 Pa, wind 410 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

34Jan60Feb98Mar115Apr138May141Jun137Jul135Aug108Sep71Oct29Nov24Dec

June: 141 kWh/kWp, December: 24 — 5.9 times less.

November: 29 against 33 in the oblast, 12.1% less.

Selyshche: plants, kWh
kWpA yearJuneDecember
55,445705120
1010,8901,410240
1516,3352,115360

Snow and wind: Чернігів

Example: a 10 kW ground frame

For the loads of Chernihiv: 11.16 kWp, 18 panels, 389 kg of steel, 12 piles, materials ≈ 52,358 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Koriukivskyi RaionChernihiv Oblast: rayons and towns

Free calculators

Sources