Solar plant: site data
Solar power plant in Roshcha, Novhorod-Siverskyi Raion, Chernihiv Oblast
Roshcha: 1,093 kWh per kWp a year, tilt 39° 2° east of south (PVGIS). 1.3% below the oblast median (1,108). #70 of 247 in the rayon, #1124 of 1558 in the oblast.
Novhorod-Siverskyi, the rayon centre, is 35 km away. 161 m above sea level. 35 km away: Novhorod-Siverskyi, the nearest bigger centre, 1,083 — 0.9% more here. Snow and wind from the nearest regional centre in the DBN — Чернігів, 141 km. 15.27 m between rows, pitch 18.99 m (latitude 52.2°).
- Yield of 1 kWp
- 1,093kWh/year
- Tilt
- 39°2° east of south
- 10 kW
- 10,931kWh/year
- Row pitch
- 18.99m · GCR 0.25
- T_min
- -40 °Cregion I, north-western
- Snow S₀ / wind W₀
- 1,720 / 410Pa
Ground frame designer
A ground frame for a solar plant: Roshcha
The designer opens with this place’s coordinates, latitude 52.2° for the row spacing and the DBN loads of the nearest regional centre — Чернігів, 141 km: snow 1,720 Pa, wind 410 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
June: 140 kWh/kWp, December: 25 — 5.6 times less.
February: 63 against 57 in the oblast, 10.5% more.
| kWp | A year | June | December |
|---|---|---|---|
| 5 | 5,466 | 700 | 125 |
| 10 | 10,931 | 1,400 | 250 |
| 15 | 16,397 | 2,100 | 375 |
Example: a 10 kW ground frame
For the loads of Chernihiv: 11.16 kWp, 18 panels, 389 kg of steel, 12 piles, materials ≈ 52,358 UAH.
How these numbers are computed
Nearby
- Kostobobriv2 km1,093 kWh/kWp
- Serhiivske5 km1,084 kWh/kWp
- Yamne6 km1,089 kWh/kWp
- Andriyivka6 km1,088 kWh/kWp
- Leonivka6 km1,089 kWh/kWp
- Froly7 km1,080 kWh/kWp
All places: Novhorod-Siverskyi RaionChernihiv Oblast: rayons and towns
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.