Solar plant: site data

Solar power plant in Romanivshchyna, Prylutskyi Raion, Chernihiv Oblast

Romanivshchyna: 1,116 kWh per kWp a year, tilt 38° 2° east of south (PVGIS). 0.7% above the oblast median (1,108). #225 of 285 in the rayon, #450 of 1558 in the oblast.

Pryluky, the rayon centre, is 30 km away. 157 m above sea level. 30 km away: Pryluky, the nearest bigger centre, the same 1,116. Snow and wind from the nearest regional centre in the DBN — Чернігів, 101 km. 13.24 m between rows, pitch 17.01 m (latitude 50.9°).

Yield of 1 kWp
1,116kWh/year
Tilt
38°2° east of south
10 kW
11,157kWh/year
Row pitch
17.01m · GCR 0.28
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,720 / 410Pa

Ground frame designer

A ground frame for a solar plant: Romanivshchyna

The designer opens with this place’s coordinates, latitude 50.9° for the row spacing and the DBN loads of the nearest regional centre — Чернігів, 101 km: snow 1,720 Pa, wind 410 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

36Jan59Feb97Mar116Apr139May141Jun142Jul139Aug111Sep77Oct34Nov25Dec

July: 142 kWh/kWp, December: 25 — 5.7 times less.

December: 25 against 24 in the oblast, 4.2% more.

Romanivshchyna: plants, kWh
kWpA yearJulyDecember
55,579710125
1011,1571,420250
1516,7362,130375

Snow and wind: Чернігів

Example: a 10 kW ground frame

For the loads of Chernihiv: 11.16 kWp, 18 panels, 389 kg of steel, 12 piles, materials ≈ 52,358 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Prylutskyi RaionChernihiv Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.