Solar plant: site data

Solar power plant in Lozova, Koriukivskyi Raion, Chernihiv Oblast

Lozova: 1,100 kWh per kWp a year, tilt 38° 2° east of south (PVGIS). 0.8% below the oblast median (1,108). #74 of 220 in the rayon, #1039 of 1558 in the oblast.

Koryukivka, the rayon centre, is 28 km away. 124 m above sea level. 28 km away: Koryukivka, the nearest bigger centre, 1,085 — 1.4% more here. Snow and wind from the nearest regional centre in the DBN — Чернігів, 86 km. 14.09 m between rows, pitch 17.86 m (latitude 51.6°).

Yield of 1 kWp
1,100kWh/year
Tilt
38°2° east of south
10 kW
10,995kWh/year
Row pitch
17.86m · GCR 0.27
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,720 / 410Pa

Ground frame designer

A ground frame for a solar plant: Lozova

The designer opens with this place’s coordinates, latitude 51.6° for the row spacing and the DBN loads of the nearest regional centre — Чернігів, 86 km: snow 1,720 Pa, wind 410 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

34Jan57Feb98Mar116Apr140May142Jun139Jul136Aug108Sep72Oct32Nov24Dec

June: 142 kWh/kWp, December: 24 — 5.9 times less.

October: 72 against 75 in the oblast, 4.0% less.

Lozova: plants, kWh
kWpA yearJuneDecember
55,498710120
1010,9951,420240
1516,4932,130360

Snow and wind: Чернігів

Example: a 10 kW ground frame

For the loads of Chernihiv: 11.16 kWp, 18 panels, 389 kg of steel, 12 piles, materials ≈ 52,358 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Koriukivskyi RaionChernihiv Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.