Solar plant: site data
Solar power plant in Kruhloluhivka, Nizhynskyi Raion, Chernihiv Oblast
Kruhloluhivka: 1,102 kWh per kWp a year, tilt 37° 1° east of south (PVGIS). 0.6% below the oblast median (1,108). #303 of 327 in the rayon, #984 of 1558 in the oblast.
Nizhyn, the rayon centre, is 55 km away. 138 m above sea level. 43 km away: Konotop, the nearest bigger centre, 1,110 — 0.7% less here. Snow and wind from the nearest regional centre in the DBN — Чернігів, 110 km. 13.12 m between rows, pitch 16.94 m (latitude 51.0°).
- Yield of 1 kWp
- 1,102kWh/year
- Tilt
- 37°1° east of south
- 10 kW
- 11,018kWh/year
- Row pitch
- 16.94m · GCR 0.28
- T_min
- -40 °Cregion I, north-western
- Snow S₀ / wind W₀
- 1,720 / 410Pa
Ground frame designer
A ground frame for a solar plant: Kruhloluhivka
The designer opens with this place’s coordinates, latitude 51.0° for the row spacing and the DBN loads of the nearest regional centre — Чернігів, 110 km: snow 1,720 Pa, wind 410 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
July: 144 kWh/kWp, December: 23 — 6.3 times less.
February: 50 against 57 in the oblast, 12.3% less.
| kWp | A year | July | December |
|---|---|---|---|
| 5 | 5,509 | 720 | 115 |
| 10 | 11,018 | 1,440 | 230 |
| 15 | 16,527 | 2,160 | 345 |
Example: a 10 kW ground frame
For the loads of Chernihiv: 11.16 kWp, 18 panels, 389 kg of steel, 12 piles, materials ≈ 52,358 UAH.
How these numbers are computed
Nearby
- Kalchynivka2 km1,101 kWh/kWp
- Osynivka5 km1,100 kWh/kWp
- Zelenivka5 km1,099 kWh/kWp
- Martynivka5 km1,107 kWh/kWp
- Verder5 km1,101 kWh/kWp
- Soniachne5 km1,108 kWh/kWp
All places: Nizhynskyi RaionChernihiv Oblast: rayons and towns
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.